Main Arena Floor

24,500 sq. ft. – 175’ L x 140’ W

9,728 sq ft. – 128’ L x 76’ W (with retractable seats in use)

Club Room

The Club Room provides a private atmosphere with restricted access points from the interior of the building. Typical use of this space consists of premium seat hosting, catering, reception space, etc. The space is available for pre-event and post-event needs.

Maximum capacity is 175 people.

1,798 sf (37’6” x 48’9”)

Dressing Rooms (6)

There are 6 dressing rooms within the facility. Two (2) star dressing rooms with a capacity of four (4) people, two (2) large locker rooms with a capacity of ten(10) and two (2) smaller locker rooms with a capacity of eight (8). The star dressing rooms and large locker rooms have private bathroom and shower facilities.

Media Room

Typically used to host post event media/press conferences, this space is capable of connecting to inhouse video assets and external TV trucks. This space is also a flex use space and can be used for artist meet & greets, production rooms, small meeting space, etc.

605 sf (20’1” x 30’ 4”)


Electrical

The EECU Center is well equipped to support nearly any size event. Power sources include:

Show Power (Stage Right)

  • 2 x 400 amp 3 phase (CAM-LOK)
  • 1 x 200 amp 3 phase (CAM-LOK)

Show Power (Stage Left)

  • 2 x 400 amp 3 phase (CAM-LOK)
  • 1 x 200 amp 3 phase (CAM-LOK)

Generator

The arena maintains a fully automated, emergency backup generator in the event of a
power outage. The generator provides power to handle life-safety equipment and the basic
functions of the in-house public address system.

Lighting

MUSCO Lighting system​

Touch panel-controlled system for controlling arena house lights

Spotlights​

(2) – 1290 Lycian 2000-watt spotlights

Loading Dock

Accessible from the south side of the facility, the loading area consists of the following:

  • 3 bay loading dock with hydraulic dock levelers
  • 1 roll-up door with direct truck/vehicle access to the arena floor (Door Dimensions – 12’ wide x 13’6” high)

Production Equipment

Stage – StageRight 60'W x 40'D X 5'H ​

2 sets of stairs​

Stage Barricade – CC-500 4’ StageRight barricade 128'​

​Forklift – (1) Hister 5000lbs lift 8' extensions, pneumatic tires.​

Pallet Jack (1) 300lbs​

Stanchions – 52-10' 520'​

Pipe & Drape - 125' Black ​

Bike rack – 32 x 8' 256'​

Cable Ramps 20 ADA ramps and 40 Standard ramps​

Rigging – 120,000 lb. End stage capacity, dead hang: 5000lbs ​

Low steal is 50' 5" to floor.​

Additional Production Equipment provided by Gemini Equipment

Pyrotechnics

Pyrotechnics require adequate notice, documentation/permits, insurance and approvals from the appropriate authorities. EECU production staff will assist in coordination with the State Fire Marshall and other authorities.

Rigging

  • ALL RIGGING LOADS SHALL BE SUSPENDED ONLY FROM THE MEMBERS INDICATED ON THE RIGGING LOAD PLAN HEREIN. OTHER FRAMING MEMBERS SUCH AS ROOF BEAMS AND CATWALK SUPPORT BEAMS (EXCEPT AS ALLOWED BY NOTE) SHALL NOT BE USED FOR THE SUPPORT OF RIGGING LOADS.​

 

  • THE MAXIMUM WORKING LOAD SUPPORTED BY A RIGGING BEAM. RIGGING BEAM SEGMENT OR TRUSS BOTTOM CHORD SEGMENT MARKED [5] SHALL NOT EXCEED 5,000 POUNDS. THIS LOAD MAY BE A SINGLE POINT LOAD OR A COMBINATION OF LOADS ACTING ANYWHERE ALONG THE MEMBER SO LONG AS THE TOTAL LOAD ON THE SEGMENT DOES NOT EXCEED 5,000 POUNDS. SEE NOTE BELOW FOR LIMIT ON TOTAL APPLIED RIGGING GRID LOAD.​

 

  • REFER TO LIMITS FOR MAXIMUM HANGING LOAD ORIENTATION FOR ANGULAR ORIENTATION LIMITS FOR ANY RIGGING LOAD. THE MAXIMUM PERMISSIBLE LOAD FOR LOADS WHICH FORM AN ANGLE GREATER THAN 45 DEGREES FROM VERTICAL SHALL BE REDUCED 25% FROM THE MAXIMUMS INDICATED ABOVE.​
  • THE MAXIMUM TOTAL COMBINED RIGGING LOAD CARRIED BY ANY TRUSS, INCLUDING THE RIGGING LOAD ATTRIBUTABLE TO THE RIGGING BEAMS AND GIRDERS SUPPORTED BY THE TRUSS, SHALL NOT EXCEED THE FOLLOWING:​

RIGGING LOADS DISTRIBUTION:​

TRUSS 1: 45,000 POUNDS TOTAL MAXIMUM​

TRUSS 2: 45,000 POUNDS TOTAL MAXIMUM​

TRUSS 3: 40,000 POUNDS TOTAL MAXIMUM​

MAXIMUM RIGGING LOAD​

END STAGE CONFIGURATION: 120,000LBS​

  • RIGGING LOAD LIMITS LISTED ABOVE ARE IN ADDITION TO THE FUTURE RATED SCOREBOARD CAPACITY (30,000LBS +20,000LBS HOIST.)​
  • RIGGING MEMBER SEGMENTS MARKED [5] SHALL BE IDENTIFIED WITH 2” TALL WHITE LETTERS PAINTED ON EACH SIDE OF THE MEMBER, AT THE CENTER OF THE SEGMENT, AS FOLLOWS “RIGGING CAPACITY 5,000LB”​

 

Digital Assets / Scoreboards

The EECU Center is equipped with multiple digital assets including:

Video​

Motion Rocket video control system.​

 

​LED Boards​

(1) 4-Sided Convenx LEX Motorized Centerhung Scoreboard (adjustable height)

11.48’ high x 21.33’ long​ / 896 x 1664px/ face​

*At max trim, bottom of center hung is 39’ from floor​

 

(1) LED End Wall (Located on South End of Arena)​

14.86’ high x 49.21’ long​ / 3,840 x 1,664px​

(1) LED Ribbon Board Surround

Ribbons 4K FULL–

2.46’ high x 469.16’ wide​ / 34,200 x180px​

Long A - 10,320 x 180px​ / Short A - 3,840 x 180px

End - 5,880 x 180px​

 

Short B - 3,840 x 180px​ / Long B - 10,320 x 180px

(2) LED Score Tables (Sporting Events)​

Score Tables- 3,072 x 192px​

Audio System

Audio​

EAW QX Audio System over the main bowl of the arena.

 

Clear-Com

2-channel Clear-Com System

  • 12 wired single muff headsets with A/B channel packs

 

Assisted Listening Devices

  • Listen Technologies devices

Stage

Stage – StageRight 60'W x 40'D X 5'H ​

2 sets of stairs​

Parking

Backstage parking is located adjacent to the loading dock. There are 3 bays for semi-truck loading/unloading. Adjacent to this space is sufficient room for 4 tour busses with shore power supply (2 x 400 amp, 3 phase & 1 x 200 amp, 3 phase (CAMLOCK)).

Additional vehicle parking is available in for runners, etc.